Skip to main content

Volume 3 Supplement 1

ESICM LIVES 2015

  • Poster presentation
  • Open access
  • Published:

Comparison of efficiency between i-gel blind intubation and i-gel-assisted bronchoscopic intubation during cardiopulmonary resuscitation: randomized simulation study

Introduction

i-gel has been used as a conduit for blind and bronchoscopic operative intubation. However, it is not easy that conventional polyvinyl chloride (PVC) tracheal tube pass through i-gel in emergent intubation during cardiopulmonary resuscitation. We considered wire-reinforced silicone tube could pass through i-gel more easily than conventional PVC tube.

Objectives

This study aimed to compare intubation performances among i-gel blind intubation (IGI), i-gel bronchoscopic intubation (IBRI) and intubation using Macintosh laryngoscope (MCL) applying two kinds of endotracheal tube during chest compressions. We hypothesized that IGI using wire-reinforced silicone tube could achieve tracheal intubation most rapidly and successfully.

Methods

In 23 emergency physicians, a prospective randomized crossover study was conducted to examine the three intubation techniques using two kinds of endotracheal tube. Primary outcomes were the intubation time. Secondary outcomes were the cumulative success rate for intubation.

Results

The mean intubation time using IGI was shorter (p < 0.017) than that of IBRI and MCL in both endotracheal tubes (17.6 vs. 29.3 vs. 20.2 in conventional PVC tube; 14.6 vs. 27.4 vs. 19.9 in wire-reinforced silicone tube; sec). There were no significant (p > 0.05) differences between conventional PVC and wire-reinforced silicone tube for each intubation technique. The cumulative success rate using IGI was also shorter (p < 0.017) than that of IBRI and MCL in both endotracheal tubes.

Conclusions

IGI could be an effective intubation technique in emergent intubation during cardiopulmonary resuscitation.

References

  1. de Lloyd LJ, Subash F, Wilkes AR, Hodzovic I: A comparison of fibreoptic-guided tracheal intubation through the Ambu ® Aura-i ™, the intubating laryngeal mask airway and the i-gel ™: a manikin study. Anaesthesia. 2015, 70 (5): 591-597. 10.1111/anae.12988.

    Article  PubMed  CAS  Google Scholar 

  2. Gatward JJ, Thomas MJ, Nolan JP, Cook TM: Effect of chest compressions on the time taken to insert airway devices in a manikin. Br J Anaesth. 2008, 100 (3): 351-356. 10.1093/bja/aem364.

    Article  PubMed  CAS  Google Scholar 

  3. Gatward JJ, Cook TM, Seller C, Handel J, Simpson T, Vanek V, Kelly F: Evaluation of the size 4 i-gel airway in one hundred non-paralysed patients. Anaesthesia. 2008, 63 (10): 1124-1130. 10.1111/j.1365-2044.2008.05561.x.

    Article  PubMed  CAS  Google Scholar 

  4. Jackson KM, Cook TM: Evaluation of four airway training manikins as patient simulators for the insertion of eight types of supraglottic airway devices. Anaesthesia. 2007, 62 (4): 388-393. 10.1111/j.1365-2044.2007.04983.x.

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by/4.0), which permits use, duplication, adaptation, distribution, and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kim, W., Choi, H., Jang, Y. et al. Comparison of efficiency between i-gel blind intubation and i-gel-assisted bronchoscopic intubation during cardiopulmonary resuscitation: randomized simulation study. ICMx 3 (Suppl 1), A547 (2015). https://doi.org/10.1186/2197-425X-3-S1-A547

Download citation

  • Published:

  • DOI: https://doi.org/10.1186/2197-425X-3-S1-A547

Keywords