Skip to main content

Table 2 Hemodynamics parameters at the start and at the end of the daily measurements during pressure-controlled ventilation (PCV)

From: Different particle flow patterns from the airways after recruitment manoeuvres using volume-controlled or pressure-controlled ventilation

 

Start PCV

End PCV

Start PCV

End PCV

Start PCV

End PCV

Day 1

Day 1

Day 2

Day 2

Day 3

Day 3

Blood gases

 ScvO2

58 ± 7

56 ± 7

78 ± 2

76 ± 5

87 ± 4

80 ± 4

 pH

7.34 ± 0.02

7.35 ± 0.01

7.32 ± 0.02

7.33 ± 0.02

7.36 ± 0.01

7.37 ± 0.03

 Bicarbonate

30 ± 1

29 ± 1

27 ± 1

27 ± 1

27 ± 1

27 ± 1

 Base excess

6.7 ± 0.5

7 ± 1.2

3.3 ± 0.6

4 ± 0.7

3.2 ± 0.9

4 ± 0.9

 Lactate

1.3 ± 0.1

1.4 ± 0.2

0.5 ± 0.1

0.5 ± 0.1

0.5 ± 0.1

0.5 ± 0.1

Mechanical ventilation

 Volume/minute

8000 ± 294

7840 ± 271

7840 ± 271

7840 ± 271

7840 ± 271

7840 ± 271

 Breath/minute

20 ± 0

20 ± 0

20 ± 0

20 ± 0

20 ± 0

20 ± 0

 PEEP

5 ± 0

5 ± 0

5 ± 0

5 ± 0

5 ± 0

5 ± 0

 FiO2

0.5 ± 0

0.5 ± 0

0.5 ± 0

0.5 ± 0

0.6 ± 0.1

0.6 ± 0.1

 Pressure (peak)

15 ± 1

15 ± 1

16 ± 1

16 ± 1

19 ± 2

18 ± 2

 Pressure (mean)

8 ± 1

8 ± 1

8 ± 1

8 ± 1

8 ± 1

8 ± 1

Haemodynamics

 Pulse

81 ± 15

72 ± 9

74 ± 7

71 ± 3

101 ± 20

93 ± 16

 Systolic BP

108 ± 8

111 ± 11

121 ± 9

116 ± 6

132 ± 13

115 ± 11

 Diastolic BP

62 ± 8

61 ± 7

75 ± 7

68 ± 7

79 ± 17

63 ± 9

 Mean BP

77 ± 7

77 ± 7

90 ± 7

84 ± 6

96 ± 15

80 ± 9

 Saturation

96 ± 1

96 ± 1

95 ± 1

96 ± 1

92 ± 3

93 ± 2