- Poster presentation
- Open Access
- Published:
Comparative study measuring optic nerve sheath diameter by transorbital ultrasound in healthy women, pregnant women and pregnant with preeclampsia / eclampsia
Intensive Care Medicine Experimental volume 3, Article number: A992 (2015)
Introduction
Preeclampsia / eclampsia is a potentially serious disease associated with maternal complications, including neurological. In patients with increased intracranial pressure, the diameter of the optic nerve sheath increases because of its close association with the flow of cerebrospinal fluid. Her measurements using ultrasound transorbital have shown correlation with increased intracranial pressure. 20% of patients with preeclampsia, the diameter of the optic nerve sheath consistent reaches intracranial pressure values above 20 mmHg.To compare the diameter of the optic nerve sheath transorbital measured by ultrasound between healthy women, pregnant women and pregnant women with preeclampsia / eclampsia.
Objectives
To compare the diameter of the optic nerve sheath transorbital measured by ultrasound between healthy women, pregnant women and pregnant women with preeclampsia / eclampsia.
Methods
Cross-sectional, multicenter study. 3 groups were included: Group1: healthy women. Group2: women with pregnancy. Group 3: women with preeclampsia / eclampsia. We obtained urine protein, serum creatinine and platelets, blood pressure, related symptoms. Diameter 3 mm behind the eyeball and an axis perpendicular to the optic nerve was measured. Three measurements of each eye were made, averaging them to give a mean to minimize the variability of the measurement.
Results
60 patients, 20 in each group. The diameter of the optic nerve sheath was higher with statistical significance (p < 0.05) for both eyes in patients with preeclampsia / eclampsia. In group 3, 20% in the right eye and 25% in the left eye had a diameter of optic nerve sheath above 5.0 mm
Conclusions
Pregnant patients with the diagnosis of preeclampsia / eclampsia had diameters larger than the optic nerve sheath compared with women with normoevolutivos pregnancies and healthy women. In this sense, measurement transorbital DVNO by ultrasound appears as a new promissory tool, affordable, accessible and non-invasive evaluation and timely care of patients with preeclampsia / eclampsia to rule elevated intracranial pressure.
References
Dubost C, Le Gouez A, Jouffroy V, Roger-Christoph S, Benhamou D, Mercier FJ, Geeraerts T: Optic nerve sheath diameter used as ultrasonographic assessment of the incidence of raised intracranial pressure in preeclampsia: a pilot study. Anesthesiology. 2012, 116 (5): 1066-71. 10.1097/ALN.0b013e318246ea1a. May;
Heidi H, Sachita S, Keith M, Vicki N: Correlation of Optic Nerve Sheath Diameter with Direct Measurement of Intracranial Pressure. Academic Emergency Medicine. 2008, 15 (2): 201-204. 10.1111/j.1553-2712.2007.00031.x. February
Ashkan M, Shirin B, Mehrzad M: Sonographic Evaluation of Optic Nerve Diameter in Children with Raised Intracranial Pressure. JUM. 2005, 24 (2): 143-147.4. February
Author information
Authors and Affiliations
Rights and permissions
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by/4.0), which permits use, duplication, adaptation, distribution, and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
About this article
Cite this article
Ortega, J., Urias, E. & Arteaga, C. Comparative study measuring optic nerve sheath diameter by transorbital ultrasound in healthy women, pregnant women and pregnant with preeclampsia / eclampsia. ICMx 3 (Suppl 1), A992 (2015). https://doi.org/10.1186/2197-425X-3-S1-A992
Published:
DOI: https://doi.org/10.1186/2197-425X-3-S1-A992
Keywords
- Creatinine
- Pregnant Woman
- Serum Creatinine
- Optic Nerve
- Preeclampsia