Skip to main content

Table 2 Metrics for AF (test positive) versus sinus rhythm (test negative) classification on the KGH dataset. Results are shown for both the combined class samples and separately for clean and noisy subsets

From: A deep learning model for the classification of atrial fibrillation in critically ill patients

Dataset

AUROC

PPV

NPV

Sensitivity

Specificity

All

0.935

0.548

0.971

0.837

0.886

Clean

0.948

0.623

0.978

0.835

0.935

Noisy

0.856

0.451

0.921

0.841

0.646