Skip to main content

Volume 3 Supplement 1

ESICM LIVES 2015

  • Poster presentation
  • Open access
  • Published:

Diaphragmatic function assessed during an SBT trial using m-mode ultrasonography and MIP: a pilot study

Introduction

Acute respiratory failure (ARF) is characterised by a discrepancy between load imposed on respiratory muscles and their capacity. The evaluation of inspiratory muscles performance is based mainly on Maximum Inspiratory Pressure (MIP) calculation. However, MIP is determined by the contraction of all the inspiratory muscles and doesn't give information about diaphragmatic function. Recently the Diaphragmatic Displacement (DD) measured by ultrasonography has been introduced in the clinical practice to evaluate diaphragmatic function.

Objectives

We hypothesized that a correlation should exist between MIP and DD: the higher the DD, the higher the muscle performance evaluated as MIP.

Methods

ICU patients ventilated for at least 24 hours were enrolled if they met all the criteria for a spontaneous breathing trial. Exclusion criteria: age < 18 years; pregnancy;; presence of flail chest or rib fractures; pneumothorax; primary neuromuscular disease; the use of muscle-paralyzing agents within 48 hours before the study. Thirty minutes after start of the SBT, right hemi-diaphragm ultrasound scans were performed in the semi-recumbent position: DD was evaluated using a 3.5-5 MHz convex probe was placed between the eighth and tenth intercostal space, between the anterior axillary and the mid-axillary lines. Simultaneously, spirometric measurements of tidal volume (VT) and respiratory rate (RR) were performed and, finally, MIP was measured according to the technique described by Marini.

Results

We included 24 patients (mean SAPSII: 36 ± 12) admitted in the ICU for sepsis (37%), post-operatory ARF (33%), COPD (17%) and heart failure (13%). There was a significant correlation between DD and MIP values (r = 0.80; p < 0.01) (Figure 1). Similarly, there was a significant correlation between DD and VT (r = 0.63; p < 0.01) and RR (r = - 0.50; p < 0.05).

figure 1

Figure 1

Different etiologies of ARF returned differences in baseline DD. Specifically, the Bonferroni post-hoc test demonstrated that patients with sepsis evidenced lower DD than the other patients (p < 0.01).

Conclusions

We demonstrated that DD measured by ultrasonography is a specific, non-invasive and rapid diagnostic procedure that correlates well with muscle performance assessed by MIP determination, DD does not need patients' collaboration, as it is for MIP.

Author information

Authors and Affiliations

Authors

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by/4.0), which permits use, duplication, adaptation, distribution, and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Spadaro, S., Dalla Corte, F., Alvisi, V. et al. Diaphragmatic function assessed during an SBT trial using m-mode ultrasonography and MIP: a pilot study. ICMx 3 (Suppl 1), A455 (2015). https://doi.org/10.1186/2197-425X-3-S1-A455

Download citation

  • Published:

  • DOI: https://doi.org/10.1186/2197-425X-3-S1-A455

Keywords