- Poster presentation
- Open Access
- Published:
Evaluation of ivc and ijv dimensions in prediction of fluid responsiveness in spontaneous breathing patients with septic shock
Intensive Care Medicine Experimental volume 3, Article number: A594 (2015)
Introduction
Prediction of fluid responsiveness (FR) is a critical step in management of patients with septic shock. Using ultrasound in detection of inferior vena cava (IVC) diameters and collapsibility is established in mechanically ventilated patients; however its use in spontaneous breathing patients is still controversial [1]. Few studies reported a correlation between internal jugular vein dimensions and central venous pressure (CVP) [2, 3] but no data are available about the use of IJV dimensions in detection of FR.
Objectives
The aim of our study is to determine the possible rule of IVC diameters, collapsibility, and IJV dimensions in prediction of FR in spontaneous breathing patients.
Methods
Twenty spontaneous breathing patients with septic shock were included in the study. Ultrasound examination was done before fluid resuscitation. IVC minimal and maximum diameters, IVC collapsibility index (IVC maximum - IVC minimum/IVC maximum), IJV cross sectional area, IJV/Common carotid artery (CCA) ratio, and IJV aspect ratio (IJV vertical diameter/IJV transverse diameter) were measured before fluid resuscitation. Transthoracic echocardiography (TTE) was done to determine FR which was defined as increase in sub-aortic velocity time integral (VTI) > 15% after fluid bolus 7 ml/Kg. Sensitivity, Specificity and Area under receiver operating characteristic (AUROC) curves were determined for all ultrasound parameters as well as CVP for detection of FR.
Results
Eleven patients showed FR and nine patients were non-responders. APACHE II score was 16 ± 6.3, age was 36 ± 15 years. AUROC curve (95% CI) for prediction of FR was: 0.51(0.27-0.73) for CVP with sensitivity 27% and specificity 100% at cutoff value 9 mmHg, 0.5(0.27-0.72) for IJV aspect ratio, 0.56(0.33-0.78) for IJV/CCA, 0.54(0.31-0.77) for IJV surface area, 0.52(0.28-0.74) for IVC collapsibility index, 0.72(0.53-0.92) for IVC minimum diameter with sensitivity 45% and specificity 89% at cutoff value 0.3 cm, 0.76(0.48-0.90) for IVC maximum diameter with sensitivity 82% and specificity 67% at cutoff value 1.5 cm.
Conclusions
Our finding supports the evidence of the poor value of most of static parameters in prediction of FR in spontaneous breathing patients. IVC minimum and maximum diameters were the best parameters in detection of FR in our cohort.
References
Muller L, Bobbia X, Toumi M, Louart G, Molinari N, Ragonnet B, et al: Respiratory variations of inferior vena cava diameter to predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure: need for a cautious use. Crit Care. 2012, 16 (5): R188-10.1186/cc11672.
Bailey JK, McCall J, Smith S, Kagan RJ: Correlation of internal jugular vein/common carotid artery ratio to central venous pressure: a pilot study in pediatric burn patients. J Burn Care Res. 2012, 33 (1): 89-92. 10.1097/BCR.0b013e318234d965.
Keller AS, Melamed R, Malinchoc M, John R, Tierney DM, Gajic O: Diagnostic accuracy of a simple ultrasound measurement to estimate central venous pressure in spontaneously breathing critically ill patient. J Hosp Med. 2009, 4 (6): 350-355. 10.1002/jhm.503.
Author information
Authors and Affiliations
Rights and permissions
Open Access  This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made.
The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.
To view a copy of this licence, visit https://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Hasanin, A., Lotfy, A., Abdel-Aal, I. et al. Evaluation of ivc and ijv dimensions in prediction of fluid responsiveness in spontaneous breathing patients with septic shock. ICMx 3 (Suppl 1), A594 (2015). https://doi.org/10.1186/2197-425X-3-S1-A594
Published:
DOI: https://doi.org/10.1186/2197-425X-3-S1-A594
Keywords
- Septic Shock
- Inferior Vena Cava
- Maximum Diameter
- Central Venous Pressure
- Internal Jugular Vein