Dynamic changes of hepatic vein Doppler velocities predict preload responsiveness in mechanically ventilated critically ill patients

Abstract

Background

Assessment of dynamic parameters to guide fluid administration is one of the mainstays of current resuscitation strategies. Each test has its own limitations, but passive leg raising (PLR) has emerged as one of the most versatile preload responsiveness tests. However, it requires real-time cardiac output (CO) measurement either through advanced monitoring devices, which are not routinely available, or echocardiography, which is not always feasible. Analysis of the hepatic vein Doppler waveform change, a simpler ultrasound-based assessment, during a dynamic test such as PLR could be useful in predicting preload responsiveness. The objective of this study was to assess the diagnostic accuracy of hepatic vein Doppler S and D-wave velocities during PLR as a predictor of preload responsiveness.

Methods

Prospective observational study conducted in two medical–surgical ICUs in Chile. Patients in circulatory failure and connected to controlled mechanical ventilation were included from August to December 2023. A baseline ultrasound assessment of cardiac function was performed. Then, simultaneously, ultrasound measurements of hepatic vein Doppler S and D waves and cardiac output by continuous pulse contour analysis device were performed during a PLR maneuver.

Results

Thirty-seven patients were analyzed. 63% of the patients were preload responsive defined by a 10% increase in CO after passive leg raising. A 20% increase in the maximum S wave velocity after PLR showed the best diagnostic accuracy with a sensitivity of 69.6% (49.1–84.4) and specificity of 92.8 (68.5–99.6) to detect preload responsiveness, with an area under curve of receiving operator characteristic (AUC–ROC) of 0.82 ± 0.07 (p = 0.001 vs. AUC–ROC of 0.5). D-wave velocities showed worse diagnostic accuracy.

Conclusions

Hepatic vein Doppler assessment emerges as a novel complementary technique with adequate predictive capacity to identify preload responsiveness in patients in mechanical ventilation and circulatory failure. This technique could become valuable in scenarios of basic hemodynamic monitoring and when echocardiography is not feasible. Future studies should confirm these results.

Background

Expert recommendations suggest that resuscitation strategies should include the assessment of dynamic parameters to identify patients who will significantly increase cardiac output (CO) after fluid administration [1, 2]. Different techniques to predict preload responsiveness have been described in the literature [3] by testing reversible changes in preload and assessing its impact on CO or its surrogates. Each of these tests have variable diagnostic accuracies, technical nuances, and most important, often limited clinical contexts in which they can be adequately applied at the bedside [4].

Among them, passive leg raising (PLR) has become one of the most used preload responsiveness tests, due to its applicability in a wide array of scenarios, including patients in spontaneous ventilation, low tidal volume ventilation or presence of arrythmias [5]. Unfortunately, the maneuver requires either real-time CO [6] measurement through devices that are not routinely available in all intensive care units (ICU) [7], or ultrasound assessment of left ventricular outflow tract–velocity time integral (LVOT–VTI) [8], which is not always feasible to measure correctly [9]. This may be accentuated during PLR’s fast position change of the thorax, which makes image acquisition more challenging.

The Guytonian model of circulation defines that at a steady state, CO is equal to venous return (VR) [10, 11]. Moreover, directly assessing VR in daily clinical practice has proven elusive [11], even though VR is constantly manipulated by administering both fluids and vasopressors. Recent interest has emerged on the analysis of hepatic vein Doppler (HVD) through surface ultrasound as a novel window to assess physiological and pathological cardiovascular states [12, 13]. It has a specific Doppler envelope, where S and D waves represent anterograde blood flow to the right chambers during the cardiac cycle [14], and presents a high image acquisition rate [15]. Thus, tracking changes in HVD after a dynamic test such as PLR could effectively aid clinicians to identify significant changes in VR (and thus, CO), potentially predicting preload responsiveness. Unfortunately, there is paucity of data assessing this phenomenon.

The objective of this observational bi-centric prospective study was to assess the diagnostic accuracy of the changes of HVD S and D-wave velocities during a PLR maneuver as predictor of preload responsiveness in mechanically ventilated critically ill patients requiring hemodynamic resuscitation. We hypothesized that changes in HVD S and D-wave velocities would accurately predict preload responsiveness in this study population.

Methods

The study protocol was approved by the Comité Ético Científico HGF‐SSVQ (N: 07/2023), and Comité Ético Asistencial UC (N°: 220923006) and written informed consent was waived due to the observational and non-invasive nature of the study design. This study was conducted in accordance with the 1964 Declaration of Helsinki and followed the STARD guidelines for diagnostic accuracy studies [16].

Patients

Subjects older than 18 years of age who were admitted to the ICU of Hospital de Quilpué, in Quilpué, Chile and Hospital Clínico UC-Christus, in Santiago, Chile requiring controlled mechanical ventilation, in circulatory failure, and in which the attending physician performed a PLR with cardiac output assessment (PLR–CO) as part of routine clinical care were considered eligible for this study. Circulatory failure was defined as the need for vasoactive drugs to maintain MAP ≥ 65 mm Hg and the presence of at least one clinical sign of inadequate tissue perfusion, including: Lactate level > 2 mmol/l, capillary refill time > 3 s or a mottling score ≥ 1.

Exclusion criteria included the impossibility to obtain an adequate hepatic ultrasound assessment; pregnancy; S-wave reversal in hepatic vein Doppler; confirmed or suspected abdominal hypertension; chronic kidney disease in hemodialysis [17]; patients with limitations of therapeutic effort; Child C cirrhosis [18]; moderate to severe tricuspid regurgitation; cardiac arrhythmias; spontaneous ventilation; extracorporeal life support; severe respiratory failure (PaO2:FiO2 ratio of < 100 mm Hg) and/or need of PEEP > 15 cm H20.

Ultrasound measurements

A baseline ultrasound assessment was performed as part of standard hemodynamic ICU management. This included echocardiography measures such as color Doppler of the tricuspid valve, left ventricular outflow tract–velocity time integral (LVOT–VTI), lateral mitral E/E’ ratio, tricuspid annular plane systolic excursion (TAPSE), tricuspid annular systolic velocity by tissue Doppler imaging and ejection fraction (EF), which was calculated using Simpson’s biplane or Teicholz method.

The middle hepatic vein (MHV) was identified from lateral or mid-subcostal view according to previously published reports [19, 20]. A phased array transducer was used with cardiac presets to facilitate study measurements. The MHV was interrogated 2–3 cm from its junction to the inferior vena cava. Color flow Doppler was used to identify high flow parallel to the ultrasound beam and then pulsed wave Doppler was obtained. The sample volume used was 2–3 mm, with velocity range of 65–80 mm/s, and the intercept angle between the Doppler beam and the vessels’ long axis was lower than 45°. Normal hepatic vein morphology follows a triphasic pattern, including two forward and one backward related. S-wave represents forward flow during early–mid systole, D-wave represents forward flow during early–mid diastole, and A-wave represents backward flow during late diastole [12]. The maximum velocity of D and S waves, as well as the VTI of D and S waves were recorded. All Doppler findings were obtained during the end-expiratory phase of the patients´ respiratory cycle with concurrent multi-lead ECG tracings. Trained operators performed ultrasound measurements using Mindray M9 (Bio-Medical Electronics Co., Shenzhen, China).

PLR maneuver

Whenever the attending clinician performed a PLR–CO to assess fluid responsiveness status, the technique was performed according to current recommendations [21]. Baseline patient positioning was in semi-recumbent at 45º angle and ended with the trunk in supine position and both legs elevated [22], as shown in Fig. 1.

Fig. 1
figure 1

Study protocol. VTI velocity time integral

Stroke volume and cardiac output were obtained with a continuous pulse contour analysis device (Argos® Cardiac Output Monitor, Retia Medical, USA). The monitors’ refresh rate was set at 20 s to detect meaningful variations during the PLR maneuver. Arterial line transducing adequacy was checked before the PLR maneuver. The HVD measurements were repeated between 1–2 min after leg elevation, at end expiration as well. We did not measure LVOT–VTI after PLR due to the limited timeframe of the maneuver’s effect on CO (1–2 min) [6]. Due to this small window of opportunity, we focused on obtaining proper HVD measurements. During the measurement period, adequacy of arterial line transduction and a minimum tidal volume of 8 ml/kg IBW during controlled mechanical ventilation was ensured. Patients were considered preload responders if CO increased 10% or more after PLR, as suggested by previous studies and recent expert recommendations [23,24,25].

Data registry

Demographic data such as age, sex, comorbidities, Acute Physiology and Chronic Health Evaluation II (APACHE II), Sequential Organ Failure Assessment (SOFA) score, Charlson comorbidity index, diagnostic group on admission, laboratory tests, mechanical ventilation parameters [23] and clinically relevant outcomes such as ICU length of stay and 28-day mortality were registered.

Statistical analysis

Demographic variables are presented as frequency (percentage) and mean ± standard error (SD) or median [interquartile range] as appropriate, depending on data normality distribution. Receiver operating characteristic (ROC) were constructed to assess the diagnostic accuracy of HVD S and D-wave velocity and VTI changes to predict a preload responsive status. Data are presented as the area under the ROC curve (AUC–ROC) ± SD (with a 95% confidence interval), sensitivity (95% CI) and specificity (95% CI). The Youden index (sensitivity + specificity – 1) was calculated to determine the best cutoff values. The grey zone approach was performed to define cases under 90% of sensitivity and specificity (diagnostic tolerance of 10%). AUC–ROC between variables were compared according to Hanley and McNeil method [26]. We performed two exploratory sensitivity analyses: first, using a 15% increase of CO cutoff after PLR, and second, using a 10% cutoff on stroke volume (SV).

Considering previous reports [25, 27], we estimated the sample size comparing an expected AUC–ROC of 0.78 curve with the null hypothesis of 0.50, assuming a two-sided α error of 0.05 and power of 80%. In total, at least 36 cases were required to be included. A p value < 0.05 was considered statistically significant. Data were analyzed with Graphpad Prism 10.0 (Graphpad Softwares, La Joya, CA) statistical package.

Results

From August to December 2023, we screened 50 patients for eligibility and 37 met inclusion and exclusion criteria, as shown in the study flow (Additional File 1). The main patient characteristics at baseline are presented in Table 1. Median age was of 59 ± 15 years, and most had sepsis-related circulatory dysfunction. Median SOFA score was 8 [6,7,8,9,10], and median norepinephrine dose at measurement time was of 0.15 [0.06–0.37] mcg/kg/min. 8% (3/37) of patients were on vasopressin infusion as a second vasopressor. Regarding the tissue perfusion triggers that prompted clinicians to perform a PLR assessment, 40% of patients had abnormal lactate, 46% altered CRT, and 14% an altered mottling score [28].

Table 1 Baseline characteristics of study population

62% of the patients were preload responsive defined by a 10% increase in CO after PLR. Table 2 shows key hemodynamic, echocardiographic and HV Doppler variables in preload responsive and unresponsive patients. In 11% (4/37) of patients, LVOT–VTI was not assessable due to poor 5-chamber view window. Additional File 2 shows key ventilatory settings in both study groups, while Additional File 3 shows the relationship between TAPSE and Delta S-wave velocity in the whole study cohort.

Table 2 Hemodynamic parameters and ultrasound measurements according to preload responsiveness status

Figure 2 shows ROC curves of the different HVD velocities studied to predict preload responsiveness status. Among them, Delta of S-wave velocity had the higher AUC–ROC (0.82 ± 0.07, p = 0.001), as shown in Table 3, followed by delta S-wave VTI (0.76 ± 0.08, p = 0.008). No statistically significant differences were found when comparing AUC–ROC of the S-waves related variables (p = 0.58). The other variables studied (delta D-wave velocity and delta VTI D-wave), had lower diagnostic yield. Additional File 4 and 5 show ROC curves, AUC–ROC and optimal cutoff values to predict an increase of > 10% of stroke volume of the studied parameters. Additional Files 6 and 7 show ROC curves, AUC–ROC and optimal cutoff values to predict an increase of > 15% of CO, showing similar diagnostic accuracies for Delta S-wave velocity in these contexts.

Fig. 2
figure 2

Receiver operating curves of different hepatic vein Doppler parameters to identify preload responsiveness (defined by an increase of CO > 10%). VTI velocity time integral

Table 3 Diagnostic accuracy of preload responsiveness (defined by an increase of CO > 10%), and selected cutoff values for hepatic vein Doppler measurements

The optimal cutoff value was obtained for each variable through the Youden index. A 20% increase in the maximum S wave velocity after PLR showed a sensitivity of 69.6 (49.1–84.4) and specificity of 92.8 (68.5–99.6) to detect preload responsiveness, as shown in Table 3. Figure 3 shows the grey-zone approach for delta S-wave velocity, in which 33% of the study group was located between the grey-zone limits. Additional File 8 shows a plot of individual values of different HVD parameters vs. delta CO, which shows the best correlation with Delta S-wave velocity.

Fig. 3
figure 3

Grey-zone approach of delta-velocity of S-wave hepatic vein Doppler

Discussion

The main results of our study can be summarized as follows. A change of 20% of S-wave peak velocity or 25% of S-wave VTI may identify preload responsiveness during a PLR maneuver in sedated and mechanically ventilated critically ill patients. Analysis of D-wave velocities had worse predictive capacity.

The hemodynamic effects of a PLR maneuver have been estimated to mimic a fluid challenge of approximately 300 ml [21]. Current expert recommendations suggest performing the test from a semi-recumbent rather than from supine position, to induce shifts from two vascular beds (the legs and the splanchnic region) and enhance diagnostic accuracy [21]. This was hypothesized in the study by Jabot et al., in which sequential postural changes from semirecumbent to supine and from supine to leg elevation had similar net effect to that of the entire maneuver performed at once [22]. The authors inferred that the scaffolded approach isolated the relative contributions of both vascular territories (splanchnic and legs), but unfortunately, it wasn’t measured [22]. The current study provides direct assessment on the impact of PLR on splanchnic flow through Doppler assessment, potentially confirming this hypothesis. In this sense, the fact that significant changes in flow-related measurements of the splanchnic region accurately predicted changes in CO, support that the contribution of this venous reservoir is relevant, at least in this clinical context. Future research endeavors should further investigate the relative contribution of each territory in this and other clinical contexts.

Contemporary research has assessed the accuracy of splanchnic Doppler signals to predict preload responsiveness. Cheong et al. analyzed the utility of portal vein pulsatility index (PVPi), finding that a value of PVPi > 32% predicted fluid unresponsiveness with a sensitivity 30.8% (17–47.6%) and specificity of 100% (85.8–100) [29]. On the other hand, Wu et al. analyzed absolute values of S and D waves of HVD, finding higher delta S-wave velocity on patients where cardiac output increased after volume expansion as compared to those where it did not (30.1 cm/s ± 10.2 to 37.1 cm/s ± 12.5; p < 0.003) [30], moreover, no diagnostic accuracy was analyzed. Our study further expands the results obtained by these previous researchers, since they aim specifically at interrogating Doppler waves that represent forward flow to the atrium and are near inferior vena cava drainage, as compared to portal vein. Thus, we believe it has a stronger physiological background and could interrogate more directly changes in VR, explaining their increased accuracy.

Multiple tests to predict preload responsiveness have focused on measuring arterial flow-related variables to identify markers of CO increase [31], such as pulse pressure or stroke volume. Only two proposed preload responsiveness tests have focused on interrogating the venous side of circulation, namely SVC and IVC diameter variability [32, 33]. However, both present technical and conceptual challenges. The former requires transesophageal ultrasound (US) measurements [34], hindering its’ widespread applicability, while the latter has multiple technical drawbacks related to insonation angle, IVC sphericity and venous compliance, limiting its’ diagnostic accuracy [35]. The novel approach proposed on this study, which focuses on blood flow variations measured through pulsed Doppler rather than anatomical variations, such as diameter, could help overcome these issues, and approach indirectly to VR changes. Due to the angulation required, obtaining flow patterns from the IVC is not feasible, but the HV provides an adequate US assessment site that drains directly into the IVC without major valves or obstructions, becoming a valuable and emerging window for hemodynamic assessment.

Recently, the visual inspection of HVD has also been studied as a marker for venous congestion or fluid intolerance, being a pivotal component of the VExUS score [36]. S-wave reversal, which represents retrograde flow, has been proposed as a marker of hepatosplanchnic congestion. Altered VexUS has correlated to key hemodynamic parameters such as high CVP values [37], and could predict the risk of acute kidney injury in different contexts. HVD has also been used as a marker of venous congestion in heart failure context with prognostic implications as well [38]. As proposed by Kenny et al., the dynamic assessment of waveform patterns (i.e., increase in D wave or reversion of S wave) through a PLR maneuver or fluid challenge could aid in identifying potential congestion [39, 40]. Thus, HVD could be a fairly unique tool able to assess not only fluid responsiveness as seen this manuscript, but also assess fluid tolerance, which is of growing clinical importance [41, 42]. Moreover, future research efforts should answer these areas of uncertainty.

Of note, in this cohort, preload responsive patients had significantly higher baseline TAPSE readings as compared to non-responders (although median values were within normal range). Thus, it could be argued that the difference in preload responsiveness status was determined because patients had better right ventricular function, determining a steeper cardiac function curve. Recent reports such as Zhang et al. have shown that TAPSE correlates with HVD-derived indexes such as the systolic filling fraction [S-wave velocity/(S-wave + D-wave velocities)] [20]. Our results show that delta S-wave velocity correlates with TAPSE (Additional File 3). Both phenomena could be explained by the fact that during ventricular systole the tricuspid annulus moves inward to the cardiac apex, which causes a further anterograde flow during systole (thus reflected in the S wave of HVD) [14]. Moreover, this study was not designed to address this question, and clinical interpretation should be made with caution considering other key echocardiographic results obtained, but certainly it deserves further exploration.

This study has several strengths. First, it’s bicentric nature. Second, delta S-wave velocity presented an adequate AUC–ROC (> 0.8), with less than 40% of measurements in the gray zone of diagnostic tolerance. This becomes particularly relevant when considering the easiness of image acquisition, as compared to LVOT–VTI. In fact, Spiegel et al. only reported 7.9% of inadequate HVD window in a cohort of patients admitted to ICU [43], similar rate to that shown by Prager et al. in a cohort of septic shock patients [15]. Even though our study was not designed to assess image acquisition feasibility of HVD, we excluded only 4% of patients for this reason out of the eligible patients screened (Additional File 1).This contrasts significantly to the prevalence of inadequate windows to obtain LVOT–VTI, which can amount up to 22% [44, 45]. Added to the non-invasive nature of the technique, no requirement of CO monitor and its’ easier learning curve, HVD could emerge as a valuable tool at the bedside assessment of critically ill patients.

This study has several limitations. First, as all ultrasound-based assessments, the technique is operator dependent and intra or inter-observer variability could occur. Second, we decided to assess changes in CO through a PLR rather than the more classic design of administrating a fluid challenge [25] to assess fluid responsiveness. Even though the fluid challenge has been praised as a gold-standard technique, both the physiological determinants of PLR (± 300 ml of autotransfusion) and the diagnostic accuracy of its’ derived measurements (sensitivities and specificities > 85%) [24], provide a comparable alternative. This approach has already been used in the contemporary literature of diagnostic accuracy of preload responsiveness tests [46, 47], and has the added benefit of avoiding potential deleterious fluids [48, 49] to patients which are preload unresponsive. Another potential criticism could be the use of non-calibrated CO monitors such as those used in this study. Moreover, the technical determinants (i.e., pulse contour analysis) for tracking relative changes of CO are the same as those used in transpulmonary thermodilution (TPTD), and the least significant changes of CO variability has been estimated around 1%, significantly under our detection threshold of PR of 10% [50]. The multibeat pulse contour monitoring used has a short refresh rate (20 s), and presents an adequate ability to capture quick and relative changes such as those happening during a PLR, as shown in recent studies [51, 52]. There was a predominance of septic patients, which could present with higher rates of preload responsiveness [53]. Thus, this could preclude extrapolation to other diagnostic groups of circulatory failure. Since our study was the first assessment of the diagnostic accuracy of this novel technique, we decided to avoid potential physiological confounders, such as right sided valvular diseases, light sedation or patients with respiratory efforts, which could introduce bias or error and preclude a correct interpretation of results.

Future studies should confirm these results and test the diagnostic capacity of HVD in broader contexts of critical illness, such as patients with spontaneous breathing, light sedation, arrythmias or valvular diseases. Aswell, the usefulness of the dynamic assessment of fluid intolerance through identification of flow patterns of S and D waves in concomitance with preload responsiveness could aid clinicians on identifying the best balance between risk/benefit ratio on fluid administration. Finally, future studies could compare, through hand-tracking devices, the difference on number of movements and distance travelled between HVD and LVOT–VTI during a PLR maneuver [54].

In conclusion, in sedated and mechanically ventilated critically ill patients, dynamic changes of S-wave on HVD after a PLR maneuver had a suitable predictable capacity to identify preload responsiveness. This technique could become valuable in scenarios of basic hemodynamic monitoring and when cardiac US is not feasible. Future studies should confirm these results and their relationship with dynamic venous congestion assessment.

Availability of data and materials

The data sets are available from the corresponding author on reasonable request.

Abbreviations

CO:

Cardiac output

PLR:

Passive leg raising

ICU:

Intensive care unit

LVOT–VTI:

Left ventricular outflow tract–velocity time integral

VR:

Venous return

HVD:

Hepatic vein Doppler

PLR–CO:

PLR with cardiac output assessment

MAP:

Mean arterial pressure

PEEP:

Positive end-expiratory pressure

TAPSE:

Tricuspid annular plane systolic excursion

EF:

Ejection fraction

MHV:

Middle hepatic vein

VTI:

Velocity time integral

IBW:

Ideal body weight

APACHE-II:

Acute physiology and chronic health disease classification system II

SOFA:

Sequential organ failure assessment score

AUC–ROC:

Area under the curve receiver‐operating characteristic

ROC:

Receiver‐operating characteristic

PVPi:

Portal vein pulsatility index

SVC:

Superior vena cava

IVC:

Inferior vena cava

US:

Ultrasound

VexUS:

Venous excess ultrasound score

TPTD:

Transpulmonary thermodilution

References

  1. Evans L, Rhodes A, Alhazzani W et al (2021) Surviving sepsis campaign: international guidelines for management of sepsis and septic shock 2021. Intensive Care Med 47:1181–1247. https://doi.org/10.1007/s00134-021-06506-y

    Article  PubMed  PubMed Central  Google Scholar 

  2. Bakker J, Kattan E, Annane D et al (2022) Current practice and evolving concepts in septic shock resuscitation. Intensive Care Med 48:148–163. https://doi.org/10.1007/s00134-021-06595-9

    Article  PubMed  Google Scholar 

  3. Monnet X, Marik PE, Teboul JL (2016) Prediction of fluid responsiveness: an update. Ann Intensive Care 6:111

    Article  PubMed  PubMed Central  Google Scholar 

  4. Monnet X, Shi R, Teboul JL (2022) Prediction of fluid responsiveness. What’s new? Ann Intensive Care 12:46

    Article  PubMed  PubMed Central  Google Scholar 

  5. Mesquida J, Gruartmoner G, Ferrer R (2017) Passive leg raising for assessment of volume responsiveness: a review. Curr Opin Crit Care 23:237–243

    Article  PubMed  Google Scholar 

  6. Monnet X, Rienzo M, Osman D et al (2006) Passive leg raising predicts fluid responsiveness in the critically ill. Crit Care Med 34:1402–1407. https://doi.org/10.1097/01.CCM.0000215453.11735.06

    Article  PubMed  Google Scholar 

  7. Estenssoro E, Alegría L, Murias G et al (2017) Organizational issues, structure, and processes of care in 257 ICUs in Latin America: a study from the Latin America Intensive Care Network. Crit Care Med 45:1325–1336. https://doi.org/10.1097/CCM.0000000000002413

    Article  PubMed  Google Scholar 

  8. Blanco P (2020) Rationale for using the velocity–time integral and the minute distance for assessing the stroke volume and cardiac output in point-of-care settings. Ultrasound J 12:21

    Article  PubMed  PubMed Central  Google Scholar 

  9. Blanco P, Aguiar FM, Blaivas M (2015) Rapid ultrasound in shock (RUSH) velocity-time integral: a proposal to expand the RUSH protocol. J Ultrasound Med 34:1691–1700. https://doi.org/10.7863/ultra.15.14.08059

    Article  PubMed  Google Scholar 

  10. Guyton AC, Lindsey AW, Abernathy B et al (1957) Venous return at various right atrial pressures and the normal venous return curve. Am J Physiol 189:609–615

    Article  CAS  PubMed  Google Scholar 

  11. Persichini R, Lai C, Teboul JL et al (2022) Venous return and mean systemic filling pressure: physiology and clinical applications. Crit Care 26:1–11. https://doi.org/10.1186/s13054-022-04024-x

    Article  Google Scholar 

  12. Fadel BM, Alkalbani A, Husain A et al (2015) Respiratory hemodynamics in the hepatic veins—normal pattern. Echocardiography 32:585–588. https://doi.org/10.1111/echo.12744

    Article  PubMed  Google Scholar 

  13. Bang DH, Son Y, Lee YH, Yoon KH (2014) Doppler ultrasonography measurement of hepatic hemodynamics during Valsalva maneuver: healthy volunteer study. Ultrasonography 34:32–38. https://doi.org/10.14366/usg.14029

    Article  PubMed  PubMed Central  Google Scholar 

  14. Scheinfeld MH, Bilali A, Koenigsberg M (2009) Understanding the Spectral Doppler waveform of the hepatic veins in health and disease. Radiographics 29:2081–2098. https://doi.org/10.1148/rg.297095715

    Article  PubMed  Google Scholar 

  15. Prager R, Arntfield R, Wong MYS et al (2024) Venous congestion in septic shock quantified with point-of-care ultrasound: a pilot prospective multicentre cohort study. Can J Anaesth. https://doi.org/10.1007/s12630-024-02717-1

    Article  PubMed  Google Scholar 

  16. Bossuyt PM, Reitsma JB, Bruns DE et al (2015) STARD 2015: an updated list of essential items for reporting diagnostic accuracy studies. BMJ 351:h5527. https://doi.org/10.1136/bmj.h5527

    Article  PubMed  PubMed Central  Google Scholar 

  17. Provenzano M, Rivoli L, Garofalo C et al (2020) Renal resistive index in chronic kidney disease patients: possible determinants and risk profile. PLoS ONE 15:1–14. https://doi.org/10.1371/journal.pone.0230020

    Article  CAS  Google Scholar 

  18. Iranpour P, Lall C, Houshyar R et al (2016) Altered Doppler flow patterns in cirrhosis patients: an overview. Ultrasonography 35:3–12. https://doi.org/10.14366/usg.15020

    Article  PubMed  Google Scholar 

  19. Coulden RA, Lomas DJ, Farman P et al (1992) Doppler ultrasound of the hepatic veins: normal appearances. Clin Radiol 45:223–227

    Article  CAS  PubMed  Google Scholar 

  20. Zhang H, Liu Y, Zhang Q et al (2022) Hepatic vein Doppler in critically ill patients: a reflection of central venous pressure or right ventricular systolic function? BMC Anesthesiol 22:1–9. https://doi.org/10.1186/s12871-022-01872-6

    Article  Google Scholar 

  21. Monnet X, Teboul JL (2015) Passive leg raising: five rules, not a drop of fluid! Crit Care 19:18

    Article  PubMed  PubMed Central  Google Scholar 

  22. Jabot J, Teboul JL, Richard C, Monnet X (2009) Passive leg raising for predicting fluid responsiveness: importance of the postural change. Intensive Care Med 35:85–90. https://doi.org/10.1007/s00134-008-1293-3

    Article  PubMed  Google Scholar 

  23. Messina A, Chew MS, Poole D et al (2024) Consistency of data reporting in fluid responsiveness studies in the critically ill setting: the CODEFIRE consensus from the Cardiovascular Dynamic section of the European Society of Intensive Care Medicine. Intensive Care Med. https://doi.org/10.1007/s00134-024-07344-4

    Article  PubMed  Google Scholar 

  24. Monnet X, Marik P, Teboul JL (2016) Passive leg raising for predicting fluid responsiveness: a systematic review and meta-analysis. Intensive Care Med 42:1935–1947. https://doi.org/10.1007/s00134-015-4134-1

    Article  PubMed  Google Scholar 

  25. Shi R, Moretto F, Prat D et al (2022) Dynamic changes of pulse pressure but not of pulse pressure variation during passive leg raising predict preload responsiveness in critically ill patients with spontaneous breathing activity. J Crit Care 72:154141. https://doi.org/10.1016/j.jcrc.2022.154141

    Article  PubMed  Google Scholar 

  26. Hanley JA, McNeil BJ (1983) A method of comparing the areas under receiver operating characteristic curves derived from the same cases. Radiology 148:839–843. https://doi.org/10.1148/radiology.148.3.6878708

    Article  CAS  PubMed  Google Scholar 

  27. Messina A, Caporale M, Calabrò L et al (2023) Reliability of pulse pressure and stroke volume variation in assessing fluid responsiveness in the operating room: a metanalysis and a metaregression. Crit Care 27:431. https://doi.org/10.1186/s13054-023-04706-0

    Article  PubMed  PubMed Central  Google Scholar 

  28. Cecconi M, Hofer C, Teboul JL et al (2015) Fluid challenges in intensive care: the FENICE study: a global inception cohort study. Intensive Care Med 41:1529–1537. https://doi.org/10.1007/s00134-015-3850-x

    Article  PubMed  PubMed Central  Google Scholar 

  29. Cheong I, Amador EDO, Gómez RA et al (2023) Evaluating the utility of portal vein pulsatility index for detecting fluid unresponsiveness in the intensive care unit. J Cardiothorac Vasc Anesth 37:1677–1682. https://doi.org/10.1053/j.jvca.2023.05.039

    Article  PubMed  Google Scholar 

  30. Du W, Wang XT, Long Y, Liu DW (2017) Monitoring changes in hepatic venous velocities flow after a fluid challenge can identify shock patients who lack fluid responsiveness. Chin Med J (Engl) 130:1202–1210. https://doi.org/10.4103/0366-6999.205848

    Article  PubMed  Google Scholar 

  31. Alhashemi JA, Cecconi M, Hofer CK (2011) Cardiac output monitoring—an integrative perspective. Crit Care 15:214

    Article  PubMed  PubMed Central  Google Scholar 

  32. Vieillard-Baron A, Chergui K, Rabiller A et al (2004) Superior vena caval collapsibility as a gauge of volume status in ventilated septic patients. Intensive Care Med 30:1734–1739. https://doi.org/10.1007/s00134-004-2361-y

    Article  PubMed  Google Scholar 

  33. Barbier C, Loubières Y, Schmit C et al (2004) Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients. Intensive Care Med 30:1740–1746. https://doi.org/10.1007/s00134-004-2259-8

    Article  PubMed  Google Scholar 

  34. Vignon P, Repessé X, Begot E et al (2017) Comparison of echocardiographic indices used to predict fluid responsiveness in ventilated patients. Am J Respir Crit Care Med 195:1022–1032. https://doi.org/10.1164/rccm.201604-0844OC

    Article  PubMed  Google Scholar 

  35. Vignon P (2004) Evaluation of fluid responsiveness in ventilated septic patients: back to venous return. Intensive Care Med 30:1699–1701

    Article  PubMed  Google Scholar 

  36. Denault AY, Beaubien-Souligny W, Elmi-Sarabi M et al (2017) Clinical significance of portal hypertension diagnosed with bedside ultrasound after cardiac surgery. Anesth Analg 124:1109–1115. https://doi.org/10.1213/ANE.0000000000001812

    Article  PubMed  Google Scholar 

  37. Longino A, Martin K, Leyba K et al (2023) Correlation between the VExUS score and right atrial pressure: a pilot prospective observational study. Crit Care 27:205. https://doi.org/10.1186/s13054-023-04471-0

    Article  PubMed  PubMed Central  Google Scholar 

  38. Ohara H, Yoshihisa A, Ishibashi S et al (2023) Hepatic venous stasis index reflects hepatic congestion and predicts adverse outcomes in patients with heart failure. J Am Heart Assoc 12:1–14. https://doi.org/10.1161/JAHA.122.029857

    Article  Google Scholar 

  39. Kenny JES, Prager R, Rola P et al (2023) The effect of gravity-induced preload change on the venous excess ultrasound (VExUS) score and internal jugular vein Doppler in healthy volunteers. Intensive Care Med Exp 11:19. https://doi.org/10.1186/s40635-023-00504-8

    Article  PubMed  PubMed Central  Google Scholar 

  40. Kenny J-ÉS, Prager R, Rola P et al (2023) Unifying fluid responsiveness and tolerance with physiology: a dynamic interpretation of the diamond-Forrester classification. Crit Care Explor 5:e1022. https://doi.org/10.1097/cce.0000000000001022

    Article  PubMed  PubMed Central  Google Scholar 

  41. Muñoz F, Born P, Bruna M et al (2024) Coexistence of a fluid responsive state and venous congestion signals in critically ill patients: a multicenter observational proof-of-concept study. Crit Care 28:52. https://doi.org/10.1186/s13054-024-04834-1

    Article  PubMed  PubMed Central  Google Scholar 

  42. Kattan E, Castro R, Miralles-Aguiar F et al (2022) The emerging concept of fluid tolerance : a position paper. J Crit Care 71:154070. https://doi.org/10.1016/j.jcrc.2022.154070

    Article  PubMed  Google Scholar 

  43. Spiegel R, Teeter W, Sullivan S et al (2020) The use of venous Doppler to predict adverse kidney events in a general ICU cohort. Crit Care 24:615. https://doi.org/10.1186/s13054-020-03330-6

    Article  PubMed  PubMed Central  Google Scholar 

  44. Nagueh SF, Kopelen HA, Zoghbi WA (1995) Feasibility and accuracy of Doppler echocardiographic estimation of pulmonary artery occlusive pressure in the intensive care unit. Am J Cardiol 15(74):1256–1262

    Article  Google Scholar 

  45. Bergenzaun L, Gudmundsson P, Öhlin H et al (2011) Assessing left ventricular systolic function in shock: evaluation of echocardiographic parameters in intensive care. Crit Care 15:R200. https://doi.org/10.1186/cc10368

    Article  PubMed  PubMed Central  Google Scholar 

  46. Monnet X, Lai C, Teboul JL (2023) How I personalize fluid therapy in septic shock? Crit Care 27:123

    Article  PubMed  PubMed Central  Google Scholar 

  47. Maizel J, Airapetian N, Lorne E et al (2007) Diagnosis of central hypovolemia by using passive leg raising. Intensive Care Med 33:1133–1138. https://doi.org/10.1007/s00134-007-0642-y

    Article  PubMed  Google Scholar 

  48. Boyd JH, Forbes J, Nakada TA et al (2011) Fluid resuscitation in septic shock: a positive fluid balance and elevated central venous pressure are associated with increased mortality. Crit Care Med 39:259–265. https://doi.org/10.1097/CCM.0b013e3181feeb15

    Article  PubMed  Google Scholar 

  49. Malbrain MLNG, Marik PE, Witters I et al (2014) Fluid overload, de-resuscitation, and outcomes in critically ill or injured patients: a systematic review with suggestions for clinical practice. Anaesthesiol Intensive Ther 46:361–380. https://doi.org/10.5603/AIT.2014.0060

    Article  PubMed  Google Scholar 

  50. de Courson H, Ferrer L, Cane G et al (2019) Evaluation of least significant changes of pulse contour analysis-derived parameters. Ann Intensive Care 9:116. https://doi.org/10.1186/s13613-019-0590-z

    Article  PubMed  PubMed Central  Google Scholar 

  51. Hernández G, Valenzuela ED, Kattan E et al (2024) Capillary refill time response to a fluid challenge or a vasopressor test: an observational, proof-of-concept study. Ann Intensive Care 14:49. https://doi.org/10.1186/s13613-024-01275-5

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  52. Bitker L, Noirot I, Chauvelot L, Mezidi M, Dhelft F, Gaillet M, Yonis H, Deniel G, JR, (2024) Evaluation of bias and trending ability of non-calibrated multi-beat analysis continuous cardiac output monitoring in critically patients. Crit Care 28:P080. https://doi.org/10.1186/s13054-024-04822-5

    Article  Google Scholar 

  53. Cooke K, Sharvill R, Sondergaard S, Aneman A (2018) Volume responsiveness assessed by passive leg raising and a fluid challenge: a critical review focused on mean systemic filling pressure. Anaesthesia 73:313–322. https://doi.org/10.1111/anae.14162

    Article  CAS  PubMed  Google Scholar 

  54. Kattan E, De la Fuente R, Putz F et al (2020) Simulation-based mastery learning of bronchoscopy-guided percutaneous dilatational tracheostomy: competency acquisition and skills transfer to a cadaveric model. Simul Healthc. https://doi.org/10.1097/SIH.0000000000000491

    Article  Google Scholar 

Download references

Acknowledgements

None.

Funding

This study has been funded by FONDECYT ANID Grant N° 1230475.

Author information

Authors and Affiliations

Authors

Contributions

MB, FM and EK contributed to the study conception, and design. MB, SA, FM, LC, CG, RC, RU and MH contributed to clinical conduction of the study. MB, FM, CG, JR, RC, AW, GH and EK contributed to statistical analysis and interpretation. MB, FM, RU, JR, RC, PR, AW, ERA, RC, GH and EK contributed on the manuscript drafting. All authors have read and approved the manuscript.

Corresponding author

Correspondence to Eduardo Kattan.

Ethics declarations

Ethics approval and consent to participate

The study protocol was approved by the Comité Ético Científico HGF‐SSVQ (N: 07/2023), and Comité Ético Asistencial UC (N°: 220923006) and written informed consent was waived due to the observational and non-invasive nature of the study design.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Additional File 1. Study flow

Additional File 2. Ventilatory parameters of the study cohort.

Additional File 3. Linear relationship between Delta S-wave velocity and TAPSE.

40635_2024_631_MOESM4_ESM.docx

Additional File 4. Diagnostic accuracy of preload responsiveness (defined by an increase of stroke volume > 10%), and selected cutoff values for hepatic vein Doppler measurements.

40635_2024_631_MOESM5_ESM.tif

Additional File 5. Receiver operating curves of different hepatic vein Doppler parameters to identify preload responsiveness (defined by an increase of stroke volume > 10%).

40635_2024_631_MOESM6_ESM.docx

Additional File 6. Diagnostic accuracy of preload responsiveness (defined by an increase of cardiac output > 15%), and selected cutoff values for hepatic vein Doppler measurements

40635_2024_631_MOESM7_ESM.tif

Additional File 7. Receiver operating curves of different hepatic vein Doppler parameters to identify preload responsiveness (defined by an increase of cardiac output  > 15%).

40635_2024_631_MOESM8_ESM.tif

Additional File 8. Linear relationship between HVD velocities variation and cardiac output variation. CO: cardiac output; VTI: velocity time integral.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Bruna, M., Alfaro, S., Muñoz, F. et al. Dynamic changes of hepatic vein Doppler velocities predict preload responsiveness in mechanically ventilated critically ill patients. ICMx 12, 46 (2024). https://doi.org/10.1186/s40635-024-00631-w

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s40635-024-00631-w

Keywords