- Letters to the Editor
- Open access
- Published:
Fugitive medical and patient-derived aerosol particle distribution following heparin nebulization in patients with COVID-19 acute hypoxemic respiratory failure: a secondary analysis of the CHARTER study
Intensive Care Medicine Experimental volume 12, Article number: 73 (2024)
To the Editor,
Aerosolisation is an effective delivery mechanism for direct delivery of therapeutics into the lung and has the potential to reduce systemic side effects. However, the potential for and extent of environmental contamination associated with aerosolisation needs to be determined, particularly whether this is influenced by oxygen delivery devices. The aim of this study was to determine the distribution of fugitive medical and patient-derived aerosols around the bed spaces of patients undergoing the management of COVID-19 pneumonia and determine differences in the aerosol particle distribution based on device used for respiratory support. A convenience sample of patients from the ‘Can Nebulised HepArin Reduce acuTE lung injury in Patients with SARS-CoV-2 Requiring Mechanical Ventilation in Ireland (CHARTER-Ireland)’ study, a randomized-controlled trial of nebulized unfractionated heparin in ICU patients with SARS-CoV-2 requiring advanced respiratory support, participated in this research [1]. An optical particle sizer (OPS 3300, TSI, Inc., USA) with an inflow hose was attached to the sampling port at the nursing station near the patients' bed space. This setup measured fugitive aerosols (FA) generated over a 24-h period during which the patient was enrolled. Measurements were recorded at 1-min intervals throughout the 24 h. Details on background, ethics, and methodology are outlined in the supplementary appendix. A total of 20 separate periods of air sampling collection were recorded on 12 patients, of which 14 were episodes from patients randomized to the heparin treatment and 6 to standard care. All patients underwent advanced respiratory support with 10 managed with high-flow nasal cannula oxygen (HFNO), 7 managed with continuous positive airway pressure (CPAP), and 3 managed with invasive mechanical ventilation (IMV). Details on patients and outcomes are outlined in supplementary Table 1. Peak particle mass concentrations were significantly higher for patients on HFNO compared to CPAP and IMV [23(4.3–37), 1.7 (0.2–4), 0.98 (0.7–2.9) µg/m3, respectively, p < 0.0001] (Fig. 1A). The median particle mass concentration over a 24-h period was also higher in the HFNO group compared to CPAP and IMV [24.6(17.2–35.5), 2.1 (0.1–28.3) vs. 3.3 (1.6–7.8) µg/m3, p = 0.0008)], with no statistically significant differences between CPAP and IMV (p = 0.9). In the group of patients receiving nebulised heparin, there was no difference in median peak particle concentration over a 24-h period in those administered heparin compared to standard care (36.1(8.4–56.3) vs. 12.6(4.7–25.5) µg/m3, p = 0.1). In all patient groups receiving nebulized heparin, there was no difference in peak particle concentration during periods of heparin nebulisation, compared to periods between treatments (23.1 (4.3–36.8) vs. 21.8(14–25.2) µg/m3, p = 0.7) nor was there a different in median peak particle concentration over a 24 h period in those receiving aerosolized heparin vs standard care for HFNO, NIV, and IMV, respectively (Fig. 1B). In conclusion, there were significant differences in FA generation depending on the type of respiratory support, showing that use of HFNO therapy results in higher FA generation compared to CPAP and IMV. Reassuringly, the nebulization of heparin did not increase FA levels compared to standard care.
Availability of data and materials
Data are available to investigators on reasonable request; please email lead author.
Abbreviations
- SOC:
-
Standard of care
- ICU:
-
Intensive Care Unit
- HFNO:
-
High flow nasal cannula oxygen
- IMV:
-
Invasive mechanical ventilation
- CPAP:
-
Continuous positive airway pressure
- FA:
-
Fugitive aerosols
- OPS:
-
Optical particle sizer
- CHARTER:
-
Can Nebulised HepArin Reduce acuTE lung injury in Patients with SARSCoV-2 Requiring Mechanical Ventilation in Ireland (CHARTER)
- VMN:
-
Vibrating mesh nebuliser
Reference
Sheehan JR, Calpin P, Kernan M, Kelly C, Casey S, Murphy D, Alvarez-Iglesias A, Giacomini C, Cody C, Curley G et al (2022) The CHARTER-Ireland trial: can nebulised heparin reduce acute lung injury in patients with SARS-CoV-2 requiring advanced respiratory support in Ireland: a study protocol and statistical analysis plan for a randomised control trial. Trials 23(1):774
Acknowledgements
Not applicable.
CHARTER Clinical trial Group: David Cosgrave1, Ciara Hanley1, Camilla Giacomini1, John Robert Sheehan1, Padraig Calpin1, Maeve Kernan1, Claire Kelly1, Siobhan Casey1, Darragh Murphy2, Claire Masterson1, Daniel O’Toole1.
1Department of Anaesthesia and Intensive Care Medicine, University Hospital Galway, Ireland.
Funding
This work was funded by a Grant from Science Foundation Ireland to Cúram, the SFI Centre for Research in Medical Devices (Research Centre Award Reference: 13/RC/2073).
Author information
Authors and Affiliations
Contributions
BM, JL, D’OT, RM, and MM conceived of the study, participated in its design and coordination, and helped to draft the manuscript; MM and RM analysed device data outputs; DC, RS, PC, MK, CK SC, DM CG, CH, and CM participated in study coordination, device set up and data collection, clinical data collection, and helped to draft the manuscript; MW, RM, D’OT, BM, JL, and MM performed the statistical analysis data interpretation and helped to draft the manuscript; all authors read and approved the final manuscript.
Corresponding author
Ethics declarations
Ethics approval and consent to participate
Ethics approval was obtained from the National Research Ethics Committee (NREC) in Ireland, Approval No. 20-NREC-COV-104. Regulatory approval for the study was obtained from the Health Products Regulatory Authority, Approval No. CT0900/650/001 Heparin Sodium.
Consent for publication
Not applicable.
Competing interests
JL had received consulting fees from Cellenkos Inc. JL is a member of the Editorial Board of ICM experimental. All other authors declare that they have no competing interests. MM and RM are employees of Aerogen Ltd. RM is named inventor on several vibrating mesh patents.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Walsh, M., Mac Giolla Eain, M., MacLoughlin, R. et al. Fugitive medical and patient-derived aerosol particle distribution following heparin nebulization in patients with COVID-19 acute hypoxemic respiratory failure: a secondary analysis of the CHARTER study. ICMx 12, 73 (2024). https://doi.org/10.1186/s40635-024-00659-y
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/s40635-024-00659-y